Anonymous User
  Sunday, 07 November 2021
  1 Replies
  2.9K Visits
0
Votes
Undo
  Subscribe

Hello EWM experts!

I pack inbound delivery item into 2-level HU in t-code /SCWM/PRDI.

1 level: 10 ST product into 1 CAR. (Create HU)

2 level: 10 CAR into 1 PAL. (Create HU)

I created WT with warehouse process type 1010 for Putaway.

I log on in /SCWM/RFUI and scan HU number (= pallet).

 

The system offers to fill next fields:

source storage bin, source HU, product, batch, quantity.

 

Why system offers to fill product, batch and quantity, if i packed it into HU (=car)?

Where could I make a mistake in customizing?

 

Thanks,

Roman Karpenko

Accepted Answer
0
Votes
Undo

Hey guys, I Made this setting, now everything works as I wanted.

Perhaps someone needs a description of the customizing, if you want scan only HU (source and destination) and storage bin (destination) in putaway.

1) SCM Extended Warehouse Management -> Extended Warehouse Management -> Mobile Data Entry -> Verification Control ->Define Warehouse-Specific Verification

2) SCM Extended Warehouse Management -> Extended Warehouse Management -> Mobile Data Entry -> Verification Control->Define Warehouse-Specific Verification Determination

Technical data.

1)Data is written to tables:

/scwm/tvprf_cnt

/scwm/tvprf_det

 

2)The system makes these checks in the functional module /SCWM/VERIFICATION_PROFILE_DET.

 

Thanks,

Roman Karpenko

Ayhan Akkaya labelled the post as Q&A — 2 years ago
Accepted Answer
0
Votes
Undo

Hey guys, I Made this setting, now everything works as I wanted.

Perhaps someone needs a description of the customizing, if you want scan only HU (source and destination) and storage bin (destination) in putaway.

1) SCM Extended Warehouse Management -> Extended Warehouse Management -> Mobile Data Entry -> Verification Control ->Define Warehouse-Specific Verification

2) SCM Extended Warehouse Management -> Extended Warehouse Management -> Mobile Data Entry -> Verification Control->Define Warehouse-Specific Verification Determination

Technical data.

1)Data is written to tables:

/scwm/tvprf_cnt

/scwm/tvprf_det

 

2)The system makes these checks in the functional module /SCWM/VERIFICATION_PROFILE_DET.

 

Thanks,

Roman Karpenko

Ayhan Akkaya selected the reply #1342 as the answer for this post — 2 years ago
There are no replies made for this post yet.